To meet the test requirements,Correct selection is required before procurement. If you are a direct user,We will arrange technical personnel to communicate with you. If you are a distributor, please provide detailed parameters of the tested product as much as possible. We can provide Free selection service,You don't need to worry about whether to purchase or not. Worldwide debugging services,No matter how harsh your testing site may be. Perfect after-sales service,Welcome to our company for on-site inspection.
GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester
Service :
  • 1、Looking for global OEM agency services
  • 2、Appearance and image design
  • 3、Customization of optional functions
  • 4、Customized operation video
  • 5、Special technical training (remote live streaming/on-site)
  • 6、Design of special occasions and special test plans
  • 7、Integrated System Development
Technical Parameter overview

 

Output voltage 0-80kV optional
Power distortion rate <1%
Voltage increasing speed 2.0kV/s, 2.5kV/s, 3.0kV/s, 3.5kV/s optional ,Error 0.2kV/s.
Voltage accuracy 2%* reading + 2 digital
Display Large LCD screen
Electrode gap standard 2.5mm
Test time 6 times(1-6 times optional)
Static time 5 min (1-9 min optional)
Booster Capacity 1.5kVA
Power input AC220V± 10%, 50Hz±1Hz
Power 200W
Working temperature 0-40
Humidity <85%RH
Dimension 670mm*420mm*410mm
Weight 38kg

  LCD screen display.
 Single-chip control, easy to control.
 Wide range watchdog circuit to avoid system halted.
 Unique HV sampling design to make the test data entering into A/D converter directly, to avoid error caused by analog circuit, which will make measurement more accurate.
 Automatic completing all test procedures.
 1-6 times breakdown voltage value and times will be saved automatically. It will print test results.
 With over-voltage, over-current and short circuit protection.
 Portable design, easy to move.